Ascon Tecnologic ATT1 temperature and voltage converter to 4 to 20 mA signal

Converts the signal of Pt100, Ni100 temperature sensors, K, S, R, J, T, N, B, E thermocouples, voltage and resistance to a standardized current signal of 4...20 mA. Programming and data download via RFid wireless transmission (NFC)
Ascon Tecnologic ATT1 temperature and voltage converter to 4 to 20 mA signal
Ascon Tecnologic ATT1 temperature and voltage converter to 4 to 20 mA signal
Ascon Tecnologic ATT1 temperature and voltage converter to 4 to 20 mA signal (1)
46,76 EUR 38,64 EUR excl. VAT
In stock
In person in Prague:nowWith a delivery company:tomorrow
Code4T-148-000PNvstup Pt100, Pt1000, Ni1000, TČ,-10..70mV, 0-4kOhm, nap. 7-30 Vss, výstup 4-20mAProducerAscon TecnologicWarranty2 years

Ascon Tecnologic AFC1 converter programmer

Ascon Tecnologic AFC1 converter programmer
In stock
96,20 EUR excl. VAT116 EUR
  • For mounting in DIN/B temperature probe sump heads
  • High accuracy, better than 0.1°C
  • 3 user linearizations (up to 96 segments)
  • Option to disable cold end compensation
  • Suitable for increasing the immunity of the temperature sensor signal against interference over longer distances
  • Power supply directly from the current loop
  • Easy and fast configuration, reading and editing of data using a mobile phone with NFC without the need to power the transmitter
  • ATNFC configuration app for Android mobile phones can be freely downloaded from the manufacturer's website
  • Calibration according to EN 60584-1: 2013, EN60751: 2008
Measured quantityTemperature
Power supply12-24 Vac/dc
Control inputTemperature sensor
Output - relay0x
Analog outputYes
ProducerAscon Tecnologic
Record of measured quantityYes

The temperature converter in DIN/B head size converts the signal obtained from temperature probes of Pt100, Ni100, Pt1000 type, thermocouples K, S, R, J, T, N, B, E, voltage -10...70mV and resistance 0...400? / 0...4k? into a normalized current signal 4...20mA. The characteristics of these transmitters ensure high accuracy of temperature reading due to 16-bit precision A/D converter. At the same time, this solution allows you to change the scale for the output signal, adjust the linearization or perhaps adjust the filter strength of the input value.

Programming is done via RFid wireless technology (NFC) using an NFC-enabled mobile phone or the separately supplied programmer , which allows the operator to quickly perform all necessary calibrations and adjustments with the benefits of galvanic isolation thanks to wireless transmission technology. An app is available for Android mobile devices with NFC capability that allows you to program, adjust and view data in the field.

Non-volatile memory allows data logging with adjustable sampling frequency. Programming software (downloadable from the manufacturer's website) allows this data to be processed and the temperature curve to be displayed.

TECHNICAL PARAMETERS
Pt100:
Measuring range
Resistance range
Connection

-200...+620°C
18,5...320 ?
2, 3, 4 wire
Pt1000:
Measuring range
Resistance range
Connection

-200...+620°C
185...3200 ?
2 wire
Ni100:
Measuring range
Resistance range
Connection

-50...+170°C
69...223 ?
2, 3, 4 wire
TC K:
Measuring range

-260...+1380°C
TC S:
Measuring range

-40...+1780°C
TC R:
Measuring range

-40...+1780°C
TC J:
Measuring range

-200...+1220°C
TC T:
Measuring range

-260...+420°C
TC N:
Measuring range

-260...+1300°C
TC B:
Measuring range

+40...+1820°C
TC E:
Measuring range

-260...+940°C
voltage:
Measuring range

-10...+70 mV
resistance:
Measuring range

0...400?, 0...4k?
Dimensions O45 x 23 mm
Power supply 7...30 Vdc
Output 4...20 mA, 2µA resolution
Error output Adjustable, 21mA or 3.8mA
Output overcurrent protection approx. 30 mA
Maximum conversion error 0.1% of range or 0.2°C (higher of the two)
Line resistance 20? maximum
Temperature coefficient < 100 ppm
Sampling 100 ms
Response time (10...90%), without filter 200 ms
Coverage IP20
Standards CE, EN 61000-6-4, EN 61000-6-2, EN 60584-1:2013, EN 60751:2008, EN 60326-1
Operating conditions -40...+85°C
30...90% RH non-condensing
DescriptionTechnical parametersDownload

This online store saves cookies that help its proper functioning. By using our services, you agree to their use.

Detailed settingsAllow everything