| Communication Bus | RS485 |
| Measured quantity | Refrigerants / Hazardous gases / CO2 / Dust |
| Measuring part of the sensor | Spatial |
| Cable length | No cable |
| Producer | Bacharach |
The Murco MGS Modbus is a self-contained sensor for leakage of refrigerants or other hazardous gases, capable of monitoring concentrations in a range from 0 to 100,000 ppm. It uses up to three different types of sensors to operate:
Their use depends on the type of gas detected, for which the sensor is factory calibrated. The sensor can be recalibrated to another gas (one of the gases listed below, depending on the sensors used) if the situation requires it.
It is equipped with an alarm LED, an audible alarm and one alarm relay. There is a user selectable analogue output which can be configured as 4-20 mA, 0-5 V, 1-5 V, 0-10 V, 2-10 V and allows the sensor to be connected to a higher level centralised system. They can be installed in applications that require continuous leak monitoring or can also be added to existing gas leak detection solutions. Typical applications include:
- Refrigerant gas detection with ammonia sensor, carbon dioxide, hydrocarbons, halogenated hydrocarbons - HFC, HCFC, CFC.
- detection of flammable gases such as: methane, LPG, propane, butane, and hydrogen
- Detection of toxic gases such as: carbon dioxide and ammonia in refrigeration, hydrogen sulphide in wastewater treatment and carbon monoxide in underground garages
- detection of volatile organic compounds such as: acetone, benzene, carbon dioxide, chloroform, ethanol, toluene, trichloroethylene.
Suitable for: commercial/industrial refrigeration, chillers and machine rooms, supermarkets, underground garages, boiler and machine rooms, food processing - ripening/storage, hospitals, schools, chemical warehouses, greenhouses, water/wastewater processing.
Under EU Regulation 517/2014 on F-Gases, all operators of equipment containing fluorinated greenhouse gases in quantities of 500 tonnesCO2 equivalent ( e.g. 274 kg of 407F refrigerant, 127 kg - 404A/507) or greater must ensure that the equipment is equipped with a leak detection system that alerts the operator if a leak is detected. The detection system must be checked every 12 months.
The Murco MGS Modbus detector with RS485 RTU Modbus interface offers easy integration and greater connectivity with control systems (e.g. Dixell's XWEB monitoring system). It detects C02, selected hydrocarbons and refrigerants using infrared or solid state sensors. This gives customers greater control over alarm delays and setpoints.
The leak detection system can be built from a single leak sensor with one alarm level or on a larger system consisting of 6 sensors and a central unit with 2 alarm levels.
Stationary gas and refrigerant leak detector for wall mounting. MGS (Murco Gas Detect) detects all types of refrigerants, flammable gases, toxic gases, exhaust fumes, sewage gases and volatile organic compounds.
Murco MGS Modbus can detect the following gases:
| TECHNICAL PARAMETERS | |
|---|---|
| Sensor type | semiconductor |
| Range | 0...1000 ppm |
| Power supply | 12/24V dc/ac 50/60 Hz |
| Consumption | approx. 350mA |
| Alarm | LED, audible, on output terminals, RS485 Modbus |
| Internal error detection | yes, LED, output terminals |
| Analog outputs | 0-5V, 1-5V, 0-10V, 2-10V, 4-20mA |
| Digital outputs | 1x Relay 1 A / 24 V, adjustable delay RS485 Modbus |
| Dimensions | 86 x 142 x 53mm |
| Enclosure | IP41 |
This online store saves cookies that help its proper functioning. By using our services, you agree to their use.