Carel DN33C0LR00 cooling thermostat with 4 DIN rail outputs

Power supply 12-24 Vac/dc, 2x NTC input, 3x digital input, 4x output relay, buzzer
Carel DN33C0LR00 cooling thermostat with 4 DIN rail outputs
121 EUR 99,98 EUR excl. VAT
In stock
In person in Prague:tomorrowWith a delivery company:2 to 3 days
Code5C-070-022PNDIN, napájení 12-24 Vstř/ss, 4x relé, bzučákProducerCarelWarranty2 years

Dixell NS6 NTC temperature probe

Dixell NS6 NTC temperature probe
In stock
6,29 EUR excl. VAT7,61 EUR

Dixell NT6 NTC temperature probe for piping

Dixell NT6 NTC temperature probe for piping
In stock
10,28 EUR excl. VAT12,44 EUR

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,64 EUR excl. VAT5,61 EUR
  • 4x output relays for:
    • compressor
    • defrosting
    • evaporator fan
    • light / auxiliary output
  • 2x NTC input
  • 3x digital input
Power supply12-24 Vac/dc
Design (panel size)DIN
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay4x
Display digit colourGreen
ProducerCarel

Carel DN33C0LR00 (Carel ir33DIN) models are suitable for controlling cooling units (with evaporator fan) with above-zero and below-zero temperatures. The controllers display the temperature and switch the compressor (or solenoid valve) according to the desired value. They can also automatically defrost the reversing circuit or heating rods according to set time parameters and control lighting. The controller can be used for temperature control during cooling (direct mode) or heating (invert mode). These functions can be easily selected by changing a parameter or digital input.

The Carel DN33S thermostat can operate not only individually, but also in a local network using external control (synchronization), without the need to lay additional cables. This feature is particularly useful and efficient in multi-cabinet applications where the entire operation of the installation must be synchronously controlled, especially with regard to defrosting. Defrosting starts simultaneously in all sections and ends independently, depending on the status of each section. When defrosting is complete, the next cooling phase starts synchronously on all sections. The local network can be used to centralize and synchronize not only the defrosting, but all functions in one display. This means that when the lighting button is pressed, for example, the command is transmitted for serial connection to all controllers, which activate the lighting relay at the same time. The same applies to the on/off, manual defrost, continuous cycle and auxiliary function commands.

TECHNICAL PARAMETERS
Power supply 12...24 Vacdc, ±10%
Power input depending on model 3 - 6 VA
Inputs 2 x NTC 3
3x digital voltage-free
Outputs 1x 16A compressor relay
1x defrost relay 16A
1x relay for discharge fan 8A
1x relay for light/auxiliary v. 8A
Dimensions 70 x 110 x 60 mm
(4 DIN modules)
Front panel enclosure IP40
Operating conditions 0...60°C, 20...80% humidity