Carel DN33F0EA00 cooling thermostat with 4 outputs on DIN rail

2x NTC input, 3x digit. 4x output relays, RS485 connector, DIN rail version
Carel DN33F0EA00 cooling thermostat with 4 outputs on DIN rail
159 EUR 131 EUR excl. VAT
On request
In person in Prague:on requestWith a delivery company:on request
Code5C-170-005PN2x NTC vstup, 3x DI vstup, 4x výst. relé, bzučák, RS 485 konektor, verze na DIN lištuProducerCarelWarranty2 years

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,73 EUR excl. VAT5,72 EUR

Dixell NS6 NTC temperature probe

Dixell NS6 NTC temperature probe
In stock
6,41 EUR excl. VAT7,76 EUR

Warning: this and other termostats DN33 were replaced by an universal thermostat Carel U20R00UC00250.

  • Four output relays for compressor, defrost, fan, light/auxiliary contact
  • 2x NTC input
  • 2x digital input
  • Buzzer for local alarm reporting
Power supply230 Vac
Design (panel size)DIN
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay4x
Communication BusRS485
Display digit colourGreen
ProducerCarel

Carel DN33F0EA00(Carel ir33DIN) controller models are suitable for controlling cooling units with evaporator fan. The controllers display the temperature and switch the compressor (or solenoid valve) according to the desired value. They can also automatically defrost the heating rods or reverse the compressor according to set time parameters. The controller can be used for temperature control during cooling (direct mode) or heating (inverse mode). These functions can be easily selected by changing a parameter or digital input.

The Carel DN33F0EA00 thermostat can operate not only individually, but also in a local network using external control (synchronization), without the need to lay additional cables. This feature is particularly useful and efficient in multi-display applications where the entire operation of the installation must be synchronously controlled. Defrosting starts simultaneously in all sections and ends independently, depending on the status of each section. When defrosting is complete, the next cooling phase starts synchronously on all sections. The local network can be used to centralise and synchronise not only the defrosting, but all functions in one display. This means that when the lighting button is pressed, for example, the command is transmitted for serial connection to all controllers, which activate the lighting relay at the same time. The same applies to the on/off, manual defrost, continuous cycle and auxiliary function commands.

 

TECHNICAL PARAMETERS
Power supply 230 Vac, ±10%, 50-60Hz
Power consumption depending on model 3 - 6 VA
Inputs 2 x NTC
3x digital voltage-free
Outputs 2x relay 16A 250Vac
2x relay 8A 250Vac
Dimensions 70 x 110 x 60 mm
(4 DIN modules)
Front panel enclosure IP40
Operating conditions 0...60°C, 20...80% humidity
DescriptionTechnical parametersDownload