Digital panel thermostat Tecnologic E33 DRRRBVVIW-E with 230V power supply

Controller for cooling with active defrost or for cooling and heating control with neutral zone.
Digital panel thermostat Tecnologic E33 DRRRBVVIW-E with 230V power supply
Digital panel thermostat Tecnologic E33 DRRRBVVIW-E with 230V power supply
Digital panel thermostat Tecnologic E33 DRRRBVVIW-E with 230V power supply (1)
93,81 EUR 77,53 EUR excl. VAT
On request
In person in Prague:on requestWith a delivery company:on request
Code4T-020-220PNnapájení 230 Vstř, vstup 3x NTC, výstup 3x relé 16+8+5A, rozměr 32x74mm, bzučákProducerAscon TecnologicWarranty2 years

NTC temperature probe Dixell NG6 - 3m

NTC temperature probe Dixell NG6 - 3m
In stock
6,54 EUR excl. VAT7,91 EUR

NTC temperature probe Dixell NS6S - 1,5m

NTC temperature probe Dixell NS6S - 1,5m
In stock
9,00 EUR excl. VAT10,89 EUR
  • For cooling applications with active defrosting or for controlling lighting or other devices
  • For cooling and heating applications
  • For cooling and heating applications with neutral zone, including control with separate setpoints for cooling and heating
  • Up to 3 NTC input sensors
  • Auxiliary digital input
  • Red display
Power supply230 Vac
Design (panel size)32 x 74 mm
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay3x
Display digit colourRed
ProducerAscon Tecnologic

The Ascon Tecnologic E33 is a digital controller, typically used in refrigeration equipment using On/Off compressor control. The controller allows for active evaporator defrost of the chiller by heating coils or reverse cycle (hot refrigerant vapor), or allows for heating/cooling control with or without a neutral zone, including the ability to control with independent setpoints for heating and cooling. The Ascon Tecnologic E33 controller also allows detailed setting of alarm conditions and the controller's behaviour when they occur and are accepted.

Up to 3 NTC temperature sensors can be connected to the Ascon Tecnologic E33 controller, or one input can be used to connect an auxiliary digital contact. For local reporting of alarm conditions, the controller includes an internal buzzer.

TECHNICAL PARAMETERS
Power supply 230 VAC +/-10% 50/60 Hz
Consumption approx. 3.5 VA
Input 3x NTC (103AT-2, 10K? @ 25°C)
Possibility to use one input for auxiliary dig. contact
Output 1x SPST 16(9)A / 250 VAC relay
1x SPDT relay 8(3)A / 250 VAC
1x SPST 5(1)A / 250 VAC relay
Temperature control ON/OFF mode
Defrost control active, interval or temperature dependent
Measuring range NTC: -50...109 °C
Accuracy ±0.5 % of range ±1 place
Operating conditions 0 ... 50°C, < 95 RH%
Dimensions 78 x 35 mm, depth 64 mm