Dixell IC291D 10110 controller for double circuit heat pumps and chillers for up to 6 compressors

Multifunction controller for centralized HVAC/R control of buildings. For chillers and heat pumps with two circuits and up to 6 compressors. RTC (Real Time Clock) and buzzer for local alarm reporting.
Dixell IC291D 10110 controller for double circuit heat pumps and chillers for up to 6 compressors
Dixell IC291D 10110 controller for double circuit heat pumps and chillers for up to 6 compressors
Dixell IC291D 10110 controller for double circuit heat pumps and chillers for up to 6 compressors (1)
Dixell IC291D 10110 controller for double circuit heat pumps and chillers for up to 6 compressors (2)
421 EUR 348 EUR excl. VAT
On request
In person in Prague:on requestWith a delivery company:on request
Code3D-300-300PNmultifunkční regulátor chillerů a tepelných čerpadel. Centralizované řízení HVAC budov.ProducerDixellWarranty2 years

Dixell PPR30 refrigerant pressure sensor, 0 to 35 bar

Dixell PPR30 refrigerant pressure sensor, 0 to 35 bar
On request
105 EUR excl. VAT127 EUR

Dixell XH20P-I humidity probe

Dixell XH20P-I humidity probe
In stock
134 EUR excl. VAT163 EUR

PTC temperature probe Dixell S6.S - 2 m

PTC temperature probe Dixell S6.S - 2 m
In stock
9,46 EUR excl. VAT11,44 EUR

Dixell LW30-KIT cable for IC200 series controllers

Dixell LW30-KIT cable for IC200 series controllers
In stock
118 EUR excl. VAT143 EUR
  • Possibility to control two circuits with up to six compressors
  • 14 adjustable output relays for compressors, fans, valves and other elements
  • 10 inputs adjustable for NTC, PTC, 4...20mA, 0...5V
  • 18 digital auxiliary adjustable inputs
  • 4 analog outputs and 2 PWM outputs for fan speed control
  • management of all types of compressors including screw compressors
  • Dynamic setpoint based control capability
  • Load balancing function between compressors
  • RTC (Real Time Clock)
  • Buzzer for local reporting of alarm conditions
  • LW30-KIT interconnecting cables are not included with the controller and must be ordered as a separate item
Power supply24 Vac/dc
Design (panel size)DIN
Type of regulationOn/off
Control inputTemperature sensor + analog signal
Auxiliary digital inputYes
Output - relay>5x
Analog outputYes
ProducerDixell

The Dixell iChill IC200 controller series is the answer to the requirements in controlling real chiller and heat pump installations. This series allows to control and manage chillers (with two circuits and up to 6 compressors, with reversibility), heat pumps and chillers. With the compact controller you get the possibility to control and monitor the following types of systems:

  • air/air
  • air/water
  • water / water
  • dehumidifiers

The advantages of these controllers include:

  • forced defrost
  • combined defrost
  • compressor cooperation
  • extraction function (for start and stop)
  • open collector output with polarity adjustment
  • load reduction function
  • alarm management even in standby mode
  • management of screw compressors
  • alarm deletion protection
  • 4...20mA, 0...10V, PWM outputs for capacitor fan control
  • NTC, 4...20mA, 0...5V analog inputs
  • load control based on dynamic setpoint
  • compressor winding switching triangle-star for start
  • internal data logger (100 alarms)
  • RTC (Real Time Clock)
  • device on/off based on time zones
  • energy saving function
  • easy programming with HotKey or ProgToolKit
  • RS485 ModBus output

The Dixell IC291D iChill controllers are designed to control two-circuit chillers, heat pumps and similar refrigeration circuits that contain up to six compressors. In addition to controlling the compressors, they can control four-way and reversing valves, process temperature and pressure protection signals, flow meters, control solenoid valves, dampers, control fan speed, start water pumps, heating coils and other components used for these systems. The Dixell IC291D iChill offers an All-in-One solution to control complex and powerful HVAC and HVAC solutions.

A typical wiring example, including the components being controlled, is shown in the following illustration.

Příklad použití Dixell IC291D

TECHNICAL PARAMETERS
Power supply 24 Vdc/Hz ±10% 50/60Hz
Consumption max. 10 VA
Inputs 6x NTC / PTC
4x NTC / 4..20mA / 0..5V
18x adjustable digital input
Outputs 14x switching relay 5(2)A 250Vac
2x analog output 4..20mA / 0..10V / PWM
4x analog output 0..10V
Other functions RTC (Real Time Clock)
Alarm buzzer
TTL output
HotKey/ProgToolKit output
VGI890 remote keypad input
Resolution 0,1°C
Connection Detachable connectors
Operating conditions -10...+55°C
20...85%RH
Accuracy ±0.7°C ±1 digit
Front panel cover IP20
Dimensions 10DIN
118 x 175 x 60 mm

Please note that the installation and especially the subsequent setup and recovery of the system is not a trivial matter and it is therefore imperative that the installation is carried out by a certified technician or contractor.

DescriptionTechnical parametersDownload

This online store saves cookies that help its proper functioning. By using our services, you agree to their use.

Detailed settingsAllow everything