Dixell XC440D 5C00E controller for condensing units with 5 outputs

DIN rail mounted, 230Vac power supply, 0/4..20mA/PTC/NTC input, 4x output relays + alarm relay + buzzer
Dixell XC440D 5C00E controller for condensing units with 5 outputs
Dixell XC440D 5C00E controller for condensing units with 5 outputs
Dixell XC440D 5C00E controller for condensing units with 5 outputs
176 EUR 145 EUR excl. VAT
In stock
In person in Prague:tomorrowWith a delivery company:2 to 3 days
Code1D-170-041PNnapájení 230 Vstř, vstup PTC/NTC/4..20mA, výstup 5x relé, TTL, montáž na DINProducerDixellWarranty2 years

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,64 EUR excl. VAT5,61 EUR

PTC temperature probe Dixell S6.S - 2 m

PTC temperature probe Dixell S6.S - 2 m
In stock
9,27 EUR excl. VAT11,22 EUR

HotKey 32 programming key for Dixell controllers

HotKey programming key for Dixell controllers
In stock
6,45 EUR excl. VAT7,80 EUR
Electronic controller for compressor systems
- control of up to 4 compressors or fans
- inputs selectable by parameter PTC/NTC/4..20mA
- recording of last 10 alarms

Power supply230 Vac
Design (panel size)DIN
Type of regulationOn/off
Control inputUniversal
Auxiliary digital inputYes
Output - relay5x
Display digit colourTwo colours
ProducerDixell

The Dixell XC440C - XC440D are controllers that can be used to control compressors or fans in a condensing unit as a whole. Compressors can be single, multi-stage or with different outputs.
The starting point for control using a neutral zone or proportionality band is the pressure or temperature sensed at the low pressure section (compressor suction) or high pressure section (condenser) of the circuit. A special algorithm balances the compressors' accrued hours to distribute the entire workload evenly.
The controller can convert the pressure reading and display it as a temperature.
The front panel offers complete information on system status, load status, condensing pressure (temperature), possible alarms or maintenance conditions. Each load has its own alarm input that can shut it down when activated.
Using the HOT KEY programming key, the controller can be easily programmed when switched on. The controller can be connected to the XJ500 monitoring unit via a TTL output using the standard ModBus RTU protocol.

TECHNICAL PARAMETERS
Power supply 230Vac, 50-60 Hz
Maximum power consumption 5 VA
Display red 3-digit and orange 4-digit
Control inputs 4-20 mA pressure sensor or NTC/PTC (optional parameter)
Digital inputs 5x voltage-free contact
Number of configurable outputs 5x switching relays 8A 250Vac
Resolution 0.1°C or 1°C
Accuracy better than 0.7% of range