| Power supply | 230 Vac |
| Design (panel size) | 32 x 74 mm |
| Type of regulation | On/off |
| Control input | Temperature sensor |
| Producer | Dixell |
| Output - relay | 1x |
| Display digit colour | Blue |
| Auxiliary digital input | Yes |
The Dixell XR20CH models are passive defrost electronic thermostats suitable for normal temperature cooling applications. They are designed for panel mounting and have front panel dimensions of 32x74 mm. They are particularly sought after for their favourable price/performance ratio, reliability, sufficient temperature range and accuracy. Deployment as a replacement for a conventional mechanical thermostat represents a significant qualitative leap in control.
Dixell XR20CH thermostats are equipped with one relay output for compressor control. Up to three PTC or NTC temperature sensors can be connected. One for temperature control, the second and third are optional (connected to the HOT KEY connector and to the dig.input) to signal a condensing temperature alarm or just to display any temperature on a remote display. The units also have a digital input for alarm signalling, for switching on the auxiliary output or for starting defrosting. The digital input can optionally be configured for a fourth temperature sensor. The HOT KEY output can be used to connect the unit (using the external XJ485-CX module) to a Dixell XWEB monitoring system. Communication is then via the ModBUS-RTU protocol. The instruments can be fully configured with parameters that can be easily programmed using the keypad or the HOT KEY programming key.
This version also has more powerful relays - load capacity 20A for resistive load, 8A for inductive load.
| TECHNICAL PARAMETERS | |
|---|---|
| Enclosure | front panel 32 x 74 mm, depth 60 mm |
| Mounting | in panel, hole 71 x 29 mm |
| Front panel enclosure | IP65 |
| Power supply | 230 Vac, ± 10% 50/60 Hz |
| Power input | 3 VA max. |
| Display | 3-digit, blue LED, digit height 18,5 mm |
| Inputs | 1x PTC (-50 to 150 °C) or NTC (-40 to 110 °C) possibility to connect 2 additional PTC/NTC auxiliary sensors |
| Outputs | 1x relay 20(8)A 250Vac |
| Additional inputs | digital voltage-free contact |
| Step | 0.1 °C or 1 °C or 1 °F (adjustable) |
| Accuracy | ±0.7 °C ±1 digit |
This online store saves cookies that help its proper functioning. By using our services, you agree to their use.