Comparison of Dixell Prime CX series:
| XR30CX | XR35CX | XR40CX | XR50CX | XR60CX | XR64CX | XR70CX | |
| Power supply | 12, 24 Vacdc, 230 Vac | 230 Vac | 12, 24 Vacdc, 230 Vac | 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac |
| Analog inputs: | |||||||
| Thermostat | NTC, PTC | NTC, Pt1000 | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC |
| Defrosting | NTC, Pt1000 | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | |
| Defrosting 2 | NTC, PTC | ||||||
| Capacitor | NTC, PTC on HotKey | NTC, Pt1000 | NTC, PTC to HotKey | NTC, PTC | NTC, PTC to HotKey | NTC, PTC to HotKey | NTC, PTC on HotKey |
| Digital inputs: | |||||||
| Alarm, defrost start, AUX, door contact, pressure switch, temperature sensor | Configurable | Configurable | Configurable | Configurable | Configurable | Configurable | Configurable |
| Alarm, defrost start, AUX, door contact, pressure switch | Configurable | ||||||
| Output relay: | |||||||
| Compressor | 8A, 20A | 8A, 16A | 8A, 20A | 20A | 8A, 16A, 20A | 8A, 16A | 8A, 16A |
| Compressor 2 | |||||||
| Defrosting | 8A | 8A | 8A | 8A, 16A | 8A, 16A | ||
| Defrosting 2 | 8A, 16A | ||||||
| Fans | 5A | 5A, 8A | 5A, 16A | 5A, 16A | |||
| Lighting / Alarm | 8A | 8A | 8A, 16A | ||||
| Defogging | |||||||
| Mixing | |||||||
| Other features: | |||||||
| Communication | TTL | RS485 | TTL | TTL | TTL | TTL | TTL |
| RTC | Optional | Optional | Optional |
| Producer | Dixell |
These Dixell XR50CX models are functionally quite comparable to the popular XR60CX models. They are particularly suitable for medium or low temperature cooling applications. They are designed for panel mounting and have dimensions of 32 × 74 mm. They are equipped with three relay outputs:
Dixell XR50CX are equipped with up to four inputs for PTC or NTC temperature sensors. One for temperature control, the second located on the evaporator (used for defrost termination temperature control and fan control), the third and fourth are optional (connected to the HOT KEY connector and to the dig.input) for signaling a condensing temperature alarm or just to display any temperature on the remote display. The units also have a digital input for alarm signalling, for switching on the auxiliary output or for defrost triggering. The digital input can optionally be configured for a fourth temperature sensor.
The HOT KEY output can be used to connect the instrument (using the external XJ485-CX module) to a Dixell XWEB monitoring system. The instruments can be fully configured with parameters that can be easily programmed using the keypad or HOT KEY programming key. The compressor output relay has a load rating of 20A (8A inductive load). The other two relays are rated at 8A (3A inductive load) and 5A (2A inductive load).
| TECHNICAL PARAMETERS | |
|---|---|
| Enclosure | front panel 32 × 74 mm, depth 60 mm |
| Mounting | in-panel, hole 29 x 71 mm |
| Front panel enclosure | IP65 |
| Power supply voltage | 230 Vac, ± 10% 50/60 Hz |
| Power input | 3 VA max |
| Display | 3-digit, red LED, digit height 14.2 mm |
| Inputs | 2x PTC (-50 to 150 °C) or NTC (-40 to 110 °C) Possibility to connect 2 additional PTC / NTC sensors |
| Additional inputs | digital voltage-free contact |
| Output - compressor | switching relay 20(8) A, 250 Vac |
| Output - defrost | switching relay 8(3) A 250Vac |
| Output - fan | switching relay 5(2) A, 250 Vac |
| Step | 0.1 °C or 1 °C (adjustable) |
| Accuracy | ± 0.7 °C ±1 digit |
This online store saves cookies that help its proper functioning. By using our services, you agree to their use.