Dixell XR70D 5N0C1 cooling controller with fan control and DIN auxiliary relay

DIN rail mounted, 230Vac power supply, 2x NTC input (-40..110 °C), 4x output relays, active defrost
Dixell XR70D 5N0C1 cooling controller with fan control and DIN auxiliary relay
Dixell XR70D 5N0C1 cooling controller with fan control and DIN auxiliary relay
Dixell XR70D 5N0C1 cooling controller with fan control and DIN auxiliary relay (1)
127 EUR 105 EUR excl. VAT
In stock
In person in Prague:nowWith a delivery company:tomorrow
Code1D-110-045PNDIN, napájení 230Vac, vstup 2x NTC (-40..110 °C), 4x výstupní relé, aktivní odtáváníProducerDixellWarranty2 years

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,73 EUR excl. VAT5,72 EUR

PTC temperature probe Dixell S6.S - 2 m

PTC temperature probe Dixell S6.S - 2 m
In stock
9,46 EUR excl. VAT11,44 EUR

HotKey 32 programming key for Dixell controllers

HotKey programming key for Dixell controllers
In stock
6,58 EUR excl. VAT7,96 EUR
  • 4 relay outputs
  • 2 inputs for NTC / PTC temperature sensors
  • easy programming
  • DIN rail mounting

Comparison of the Dixell Prime D series:

XR10D XR20D XR30D XR60D XR70D XR80D
Power supply 24, 230 Vac 24, 230 Vac 24, 230 Vac 24, 230 Vac 24, 230 Vac 24, 230 Vac
Analog inputs:
Thermostat NTC, PTC NTC, PTC NTC, PTC NTC, PTC NTC, PTC NTC, PTC
Defrosting NTC, PTC NTC, PTC
Digital inputs:
Alarm, defrost start, AUX, door contact, pressure switch Configurable Configurable Configurable Configurable Configurable
Output relay:
Compressor no 8A/ nc 5A, 20A no 8A/ nc 5A, 20A no 8A/ nc 5A, 20A no 8A/ nc 5A, 20A no 8A/ nc 5A, 20A no 8A/ nc 5A, 20A
Defrosting no 8A/ nc 5A no 8A/ nc 5A
Fans 8A 8A
Alarm no 8A/ nc 5A
Mixing no 8A/ nc 5A
Alarm or AUX no 8A/ nc 5A
Other features:
Min/max temperatures HACCP HACCP HACCP HACCP HACCP min/max

Power supply230 Vac
Design (panel size)DIN
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay4x
Display digit colourRed
ProducerDixell

The Dixell XR70D models are microprocessor-based controllers particularly suitable for medium or low temperature cooling applications. They are designed to be mounted in a DIN rail rack, where they take up space for 4 modules. They are equipped with four relay outputs: for compressor control, fan control, defrost (can be either electric or reverse cycle - hot steam) and a final, fourth relay for temperature alarm signalling. Dixell XR70Ds are equipped with two inputs for PTC or NTC temperature sensors. One for temperature control and the other, located on the evaporator, is used for defrost termination temperature control and fan control. The Dixell XR70Ds also have a digital input for alarm signaling, auxiliary output activation, door open sensor or defrost start. With the new HACCP function, the last temperature alarms are recorded to allow for follow-up.

The instruments can be fully configured with parameters that can be easily programmed using the keypad, the HOT KEY programming key or simply using a PC and the Wizmate Prog-Tool interface.

TECHNICAL PARAMETERS
Installation DIN rail mounted, 4 modules
Supply voltage 230 Vac, ± 10% 50/60 Hz
Power consumption 3 VA max
Display 3-digit, red LED, digit height 13.2 mm
Inputs 2 PTC (-50 to 150 °C) or NTC (-40 to 110 °C) sensors
Additional inputs digital voltage-free contact
Output - compressor switching relay 8(3) A, 250 Vac
Output - defrost switching relay 8(3) A, 250Vac
Output - fan switching relay 8(3) A, 250 Vac
Auxiliary output switching relay 8(3) A, 250 Vac
Step 0.1 °C or 1 °C or 1 °F (adjustable)
Accuracy ±0.7 °C ±1 digit
DescriptionTechnical parametersDownload

This online store saves cookies that help its proper functioning. By using our services, you agree to their use.

Detailed settingsAllow everything