Dixell Prime CX Series Comparison:
| XR60CX | XR64CX | XR70CX | XR72CX | XR75CX | XR77CX | XR80CX | |
| Power supply | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac |
| Analog inputs: | |||||||
| Thermostat | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, Pt1000 | NTC, Pt1000 | NTC, PTC |
| Defrosting | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, Pt1000 | NTC, Pt1000 | |
| Defrosting 2 | NTC, PTC | ||||||
| Capacitor | NTC, PTC to HotKey | NTC, PTC on HotKey | NTC, PTC on HotKey | NTC, PTC on HotKey | NTC, Pt1000 | NTC, Pt1000 | |
| Digital inputs: | |||||||
| Alarm, defrost start, AUX, door contact, pressure switch, temperature sensor | Config-able | Configurable | Configurable | Configurable | Configurable | Configurable | |
| Alarm, defrost start, AUX, door contact, pressure switch | Configurable | Configurable | Configurable | ||||
| Output relay: | |||||||
| Compressor | 8A, 16A, 20A | 8A, 16A | 8A, 16A | 8A, 16A | 8A, 16A | 8A, 12A | 8A, 20A |
| Compressor 2 | 8A, 16A | ||||||
| Defrosting | 8A | 8A, 16A | 8A, 16A | 8A, 16A | 8A | 12A | |
| Defrosting 2 | 8A, 16A | ||||||
| Fans | 5A, 8A | 5A, 16A | 5A, 16A | 5A, 16A | 5A | 5A | |
| Lighting / Alarm | 8A, 16A | 8A | 7A | ||||
| Defogging | 8A, 16A | ||||||
| Mixing | 8A | ||||||
| Other features: | |||||||
| Communication | TTL | TTL | TTL | TTL | RS485 | RS485 | TTL |
| RTC | Optional | Optional | Optional |
| Power supply | 230 Vac |
| Design (panel size) | 32 x 74 mm |
| Type of regulation | On/off |
| Control input | Temperature sensor |
| Auxiliary digital input | Yes |
| Output - relay | 4x |
| Communication Bus | RS485 |
| Display digit colour | Red |
| Producer | Dixell |
The Dixell Model XR77CX, 32 x 74 mm, is a microprocessor controller suitable for medium and low temperature cooling applications. It has 4 output relays to control compressor, fan, defrost (electric or hot gas) and light or alarm (configurable). Includes RTC (Real Time Clock) circuitry that allows programming of up to 6 defrost cycle times, split between weekdays and days off. The "Day and Night" function, in turn, allows you to set two different desired temperatures to save energy during the night hours.
It is supplied with up to four NTC or Pt1000 inputs - one for temperature control, the other for evaporator defrost and fan control on the evaporator. One of the two digital inputs can be used as a third temperature input. The fourth input can be used to set the condenser temperature alarm or to display the condenser temperature. The controller has its own separate power supply from the power line, so that peripherals with different power supply or wiring can be used.
The serial interface allows the device to be connected to an RS485 ModBUS RTU network, such as the Dixell XWEB family of monitoring systems. The HOT Key interface allows quick and easy programming using the HOT Key or ProgToolKit.
The device is fully configurable with special parameters that can be easily entered using the keypad or ProgToolKit programming interface.
| TECHNICAL PARAMETERS | |
|---|---|
| Enclosure | front panel 32 × 74 mm, depth 60 mm |
| Mounting | in-panel, opening 71 × 29 mm |
| Front panel enclosure | IP65 |
| Power supply voltage | 230 Vac, ±10% 50/60Hz |
| Power input | 3 VA max |
| Display | 3-digit, red LED, digit height 14.2 mm |
| Inputs | up to 4 NTC (-40 to 110 °C) or Pt1000 sensors |
| Additional inputs | 2x digital voltage-free adjustable contact |
| Output - compressor | switching relay 8(3) A, 250 Vac |
| Output - defrost | switching relay 12(4) A, 250Vac |
| Output - fan | switching relay 5(2) A, 250 Vac |
| Auxiliary output | switching relay 7(3) A, 250 Vac |
| Other functions | rS485 ModBus RTU serial communication RTC (Real time clock) output for remote display |
| Step | 0.1 °C or 1 °C or 1 °F (adjustable) |
| Accuracy | ±0.7 °C ±1 digit |
This online store saves cookies that help its proper functioning. By using our services, you agree to their use.