Dixell XR80CX 0P0C1 cooling thermostat with 12V power supply and mixing control

Thermostat for pasteurization, milk storage and cooling, air dryers and wherever there is a need to periodically run other equipment in addition to cooling.
Dixell XR80CX 0P0C1 cooling thermostat with 12V power supply and mixing control
Dixell XR80CX 0P0C1 cooling thermostat with 12V power supply and mixing control
Dixell XR80CX 0P0C1 cooling thermostat with 12V power supply and mixing control (1)
73,62 EUR 60,84 EUR excl. VAT
In stock
In person in Prague:nowWith a delivery company:tomorrow
Code1D-150-023PNrozměr 32x74 mm, napájení 12Vstř/ss, vstup 1xPTC/NTC, 2x výst.relé (20A pro kompresor)ProducerDixellWarranty2 years

PTC temperature probe Dixell S6.S - 2 m

PTC temperature probe Dixell S6.S - 2 m
In stock
9,46 EUR excl. VAT11,44 EUR

Dixell MDP/CX back cover for CX controllers

Dixell MDP/CX back cover for CX controllers
In stock
2,43 EUR excl. VAT2,93 EUR

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,73 EUR excl. VAT5,72 EUR
  • controllers for cooling and mixing
  • suitable for controlling feeders in dairy, food processing, air drying, etc.
  • input per PTC/NTC sensor
  • 2 output relays, one with 20A sensitivity

Dixell Prime CX series comparison:

XR60CX XR64CX XR70CX XR72CX XR75CX XR77CX XR80CX
Power supply 12, 24 Vacdc,
230 Vac
12, 24 Vacdc,
230 Vac
12, 24 Vacdc,
230 Vac
12, 24 Vacdc,
230 Vac
230 Vac 12, 24 Vacdc,
230 Vac
12, 24 Vacdc,
230 Vac
Analog inputs:
Thermostat NTC, PTC NTC, PTC NTC, PTC NTC, PTC NTC, Pt1000 NTC, Pt1000 NTC, PTC
Defrosting NTC, PTC NTC, PTC NTC, PTC NTC, PTC NTC, Pt1000 NTC, Pt1000
Defrosting 2 NTC, PTC
Capacitor NTC, PTC to HotKey NTC, PTC on HotKey NTC, PTC on HotKey NTC, PTC on HotKey NTC, Pt1000 NTC, Pt1000
Digital inputs:
Alarm, defrost start, AUX, door contact, pressure switch, temperature sensor Config-able Configurable Configurable Configurable Configurable Configurable
Alarm, defrost start, AUX, door contact, pressure switch Configurable Configurable Configurable
Output relay:
Compressor 8A, 16A, 20A 8A, 16A 8A, 16A 8A, 16A 8A, 16A 8A, 12A 8A, 20A
Compressor 2 8A, 16A
Defrosting 8A 8A, 16A 8A, 16A 8A, 16A 8A 12A
Defrosting 2 8A, 16A
Fans 5A, 8A 5A, 16A 5A, 16A 5A, 16A 5A 5A
Lighting / Alarm 8A, 16A 8A 7A
Defogging 8A, 16A
Mixing 8A
Other features:
Communication TTL TTL TTL TTL RS485 RS485 TTL
RTC Optional Optional Optional

Power supply12 Vac/dc
Design (panel size)32 x 74 mm
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay2x
Display digit colourRed
ProducerDixell

The Dixell XR80CX panel mount and XR80D DIN rail mount controller models are controllers designed for milk cooling and storage, air drying applications, or other applications that utilize the combined control of a cooling unit and additional equipment such as a fan, mixing equipment, etc. They are equipped with two relay outputs: to control the compressor of the refrigeration unit and the auxiliary equipment (fan/mixer).

These thermostats allow precise control of the entire milk storage cycle in the tanks. The auxiliary output for the agitator/fan can also be triggered by pressing a button on the controller panel, in addition to automatic start-up (which can be set via controller parameters). Parameters can be easily copied with the HOT KEY programming key and the latest temperature alarms are recorded using the new HACCP function.

Benefits and features of the Dixell XR80CX and XR80D series controllers:

  • Innovative controller suitable for normal and low temperature heating and cooling applications
  • Simple and intuitive programming
  • Direct on/off button
  • Activation of economical cooling mode via digital input
  • Fast freezing thanks to dedicated setpoint
  • Output restart on open door alarm
  • Minimum and maximum temperature functions
  • Option to set the digital input as a temperature sensor
  • Management of virtual temperature probes
  • Cycles for milk cooling and storage
  • Functions for air drying in automated processes
  • Condenser temperature management to prevent critical situations
  • HotKey or ProgTool connector for quick and easy programming
  • Serial communication allows connection to remote management systems
  • Connection for remote X-Rep display (alternative to TTL output)
  • Maximum power consumption 3VA
  • Display with status icons and 10.5mm high digits
TECHNICAL SPECIFICATIONS
Enclosure front panel 32 × 74 mm, depth 60 mm
Mounting in-panel, opening 71 × 29 mm
Input (adjustable) 1 x PTC thermistor (-50...150°C)
or NTC (-40...110°C)
Digital input - adjustable Alarm, Defrost, AUX, Door contact, Configurable pressure switch, Power saving mode
Output-compressor switching relay 20(8) A / 250 V
Output-mixer switching relay 8(3) A / 250 V
Power supply 12 Vacdc
Power input approx. 3 VA
Step 0.1 °C or 1 °C or 1 °F (adjustable)
Accuracy at 25 °C ± 0.7 °C ±1 digit
Dimensions 32 x 74 mm, depth 60 mm
Operating conditions 0...60°C, 20...80% humidity
Front panel cover IP65
DescriptionTechnical parametersDownload