Dixell Prime CX series comparison:
| XR60CX | XR64CX | XR70CX | XR72CX | XR75CX | XR77CX | XR80CX | |
| Power supply | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac |
| Analog inputs: | |||||||
| Thermostat | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, Pt1000 | NTC, Pt1000 | NTC, PTC |
| Defrosting | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, Pt1000 | NTC, Pt1000 | |
| Defrosting 2 | NTC, PTC | ||||||
| Capacitor | NTC, PTC to HotKey | NTC, PTC on HotKey | NTC, PTC on HotKey | NTC, PTC on HotKey | NTC, Pt1000 | NTC, Pt1000 | |
| Digital inputs: | |||||||
| Alarm, defrost start, AUX, door contact, pressure switch, temperature sensor | Config-able | Configurable | Configurable | Configurable | Configurable | Configurable | |
| Alarm, defrost start, AUX, door contact, pressure switch | Configurable | Configurable | Configurable | ||||
| Output relay: | |||||||
| Compressor | 8A, 16A, 20A | 8A, 16A | 8A, 16A | 8A, 16A | 8A, 16A | 8A, 12A | 8A, 20A |
| Compressor 2 | 8A, 16A | ||||||
| Defrosting | 8A | 8A, 16A | 8A, 16A | 8A, 16A | 8A | 12A | |
| Defrosting 2 | 8A, 16A | ||||||
| Fans | 5A, 8A | 5A, 16A | 5A, 16A | 5A, 16A | 5A | 5A | |
| Lighting / Alarm | 8A, 16A | 8A | 7A | ||||
| Defogging | 8A, 16A | ||||||
| Mixing | 8A | ||||||
| Other features: | |||||||
| Communication | TTL | TTL | TTL | TTL | RS485 | RS485 | TTL |
| RTC | Optional | Optional | Optional |
| Power supply | 230 Vac |
| Design (panel size) | 32 x 74 mm |
| Type of regulation | On/off |
| Control input | Temperature sensor |
| Auxiliary digital input | Yes |
| Output - relay | 2x |
| Display digit colour | Red |
| Producer | Dixell |
The Dixell XR80CX panel mount and XR80D DIN rail mount controller models are controllers designed for milk cooling and storage, air drying applications, or other applications that utilize the combined control of a cooling unit and additional equipment such as a fan, mixing equipment, etc. They are equipped with two relay outputs: to control the compressor of the refrigeration unit and the auxiliary equipment (fan/mixer).
These thermostats allow precise control of the entire milk storage cycle in the tanks. The auxiliary output for the agitator/fan can also be triggered by pressing a button on the controller panel, in addition to automatic start-up (which can be set via controller parameters). Parameters can be easily copied with the HOT KEY programming key and the latest temperature alarms are recorded using the new HACCP function.
Benefits and features of the Dixell XR80CX and XR80D series controllers:
| TECHNICAL SPECIFICATIONS | |
|---|---|
| Enclosure | front panel 32 × 74 mm, depth 60 mm |
| Mounting | in-panel, opening 71 × 29 mm |
| Input (adjustable) | 1 x PTC thermistor (-50...150°C) or NTC (-40...110°C) |
| Digital input - adjustable | Alarm, Defrost, AUX, Door contact, Configurable pressure switch, Power saving mode |
| Output-compressor | switching relay 20(8) A / 250 V |
| Output-mixer | switching relay 8(3) A / 250 V |
| Power supply | 230 Vac |
| Power input | approx. 3 VA |
| Step | 0.1 °C or 1 °C or 1 °F (adjustable) |
| Accuracy at 25 °C | ± 0.7 °C ±1 digit |
| Dimensions | 32 x 74 mm, depth 60 mm |
| Operating conditions | 0...60°C, 20...80% humidity |
| Front panel cover | IP65 |
This online store saves cookies that help its proper functioning. By using our services, you agree to their use.