Dixell Prime D series comparison:
XR10D | XR20D | XR30D | XR60D | XR70D | XR80D | |
Power supply | 24, 230 Vac | 24, 230 Vac | 24, 230 Vac | 24, 230 Vac | 24, 230 Vac | 24, 230 Vac |
Analog inputs: | ||||||
Thermostat | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC | NTC, PTC |
Defrosting | NTC, PTC | NTC, PTC | ||||
Digital inputs: | ||||||
Alarm, defrost start, AUX, door contact, pressure switch | Configurable | Configurable | Configurable | Configurable | Configurable | |
Output relay: | ||||||
Compressor | no 8A/ nc 5A, 20A | no 8A/ nc 5A, 20A | no 8A/ nc 5A, 20A | no 8A/ nc 5A, 20A | no 8A/ nc 5A, 20A | no 8A/ nc 5A, 20A |
Defrosting | no 8A/ nc 5A | no 8A/ nc 5A | ||||
Fans | 8A | 8A | ||||
Alarm | no 8A/ nc 5A | |||||
Mixing | no 8A/ nc 5A | |||||
Alarm or AUX | no 8A/ nc 5A | |||||
Other features: | ||||||
Min/max temperatures | HACCP | HACCP | HACCP | HACCP | HACCP | min/max |
Power supply | 230 Vac |
Design (panel size) | DIN |
Type of regulation | On/off |
Control input | Temperature sensor |
Output - relay | 2x |
Display digit colour | Red |
Producer | Dixell |
The Dixell XR80D DIN rail mount and XR80CX panel mount controller models are controllers designed for milk cooling and storage, air drying applications or other applications that utilize the combined control of a refrigeration unit and additional equipment such as a fan, mixing equipment, etc. They are equipped with two relay outputs: to control the compressor of the refrigeration unit and the auxiliary equipment (fan/mixer).
These thermostats allow precise control of the entire milk storage cycle in the tanks. The auxiliary output for the agitator/fan can also be triggered by pressing a button on the controller panel, in addition to automatic start-up (which can be set via controller parameters). Parameters can be easily copied with the HOT KEY programming key and the latest temperature alarms are recorded using the new HACCP function.
Benefits and features of the Dixell XR80CX and XR80D series controllers:
TECHNICAL SPECIFICATIONS | |
---|---|
Input (adjustable) | 1 x PTC thermistor (-50...150°C) or NTC (-40...110°C) |
Output-compressor | switching relay 8(3) A / 250 V |
Output-mixer | switching relay 8(3) A / 250 V |
Power supply | 230 Vac ±10 %, 50/60 Hz |
Power input | approx. 3 VA |
Accuracy at 25 °C | ± 0,7 °C |
Dimensions | 4 DIN modules (70 x 85 x 61mm) |
Operating conditions | 0...60°C, 20...80% humidity |