Dixell XT131D 5C0TU controller with neutral zone and temperature input

DIN rail mounted, power supply 230Vac, input for PTC / NTC / Pt100 / J / K / S, output 2x control relay + alarm relay
Dixell XT131D 5C0TU controller with neutral zone and temperature input
Dixell XT131D 5C0TU controller with neutral zone and temperature input
Dixell XT131D 5C0TU controller with neutral zone and temperature input
127 EUR 105 EUR excl. VAT
On request
In person in Prague:on requestWith a delivery company:on request
Code3D-080-150PNnapájení 230Vac, vstup PTC/NTC/Pt100/TC J, K, S, 2x relé + alarm.relé, neutrální zóna, DINProducerDixellWarranty2 years

HotKey 32 programming key for Dixell controllers

HotKey programming key for Dixell controllers
In stock
6,45 EUR excl. VAT7,80 EUR

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,64 EUR excl. VAT5,61 EUR

PTC temperature probe Dixell S6.S - 2 m

PTC temperature probe Dixell S6.S - 2 m
In stock
9,27 EUR excl. VAT11,22 EUR

Temperature probe - thermocouple Tecnologic FeCo - type J

Temperature probe - thermocouple Tecnologic FeCo - type J
In stock
15,72 EUR excl. VAT19,02 EUR
  • Two-state ON/OFF controller for controlling temperature, humidity, pressure, etc.
  • One analogue programmable input
  • Two control outputs for direct or inverse operation (e.g. heating/cooling)
  • Neutral zone control
  • Alarm relay

Dixell XT100D Series Comparison:

XT110D XT111D XT120D XT121D XT130D XT131D XT141D XT160D
Power supply 24Vacdc,
230Vac
24Vacdc,
230Vac
24Vacdc,
230Vac
24Vacdc,
230Vac
24Vacdc,
230Vac
24Vacdc,
230Vac
24Vacdc,
230Vac
24Vacdc,
230Vac
Inputs:
NTC, PTC, Pt100, TcJ, TcK, TcS,
or
4..20mA, 0..1V, 0..10V
1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
Digital input 1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
1x
configurable
Output relay:
Stage 1 no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A
Grade 2 no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A
Grade 3 no 8A / nc 5A
Grade 4 8A
Alarm no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A no 8A / nc 5A
Other features:
Communication TTL TTL TTL TTL TTL TTL TTL TTL
Analog output 4..20mA, 0..10V
optional
4..20mA, 0..10V
optional
4..20mA, 0..10V
optional
4..20mA, 0..10V
optional
4..20mA, 0..10V
optional
4..20mA, 0..10V
optional
4..20mA, 0..10V
optional
4..20mA, 0..10V
optional
Alarm buzzer Optional Optional Optional Optional Optional Optional Optional Optional

Power supply230 Vac
Design (panel size)DIN
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay3x
Display digit colourRed
ProducerDixell

The Dixell XT131D (DIN rail mounted) models are two-state ON/OFF controllers with a neutral zone for temperature, humidity or pressure control.

Some rooms require a type of control that is succinctly expressed by the motto "cool in summer, heat in winter". These are, for example, warehouses with poor thermal insulation.
The controller controls 2 relays, each in ON/OFF mode. The principle of this control precludes both outputs from operating simultaneously.

The relay for the heating is ON when the current temperature is lower than the desired temperature, when the temperature reaches the desired value the heating is switched off.
If the temperature continues to rise , neither output is switched on within a certain distance of the setpoint (neutral zone). If the temperature rises above the neutral zone, cooling is switched on. It operates until the temperature drops to the desired value, then switches off. If the temperature continues to fall within the neutral zone, no output is switched on; if the temperature falls below the neutral zone, the heating is switched on. The neutral zone (parameter db) is located symmetrically to the setpoint (SET), so that its boundaries lie at (SET-db/2) and (SET+db/2).

Dixell XT131D controllers are equipped with two control relays at the output and also include one alarm relay for critical condition reporting.

The analog input can be factory set to PTC, NTC, Pt100, J, K, S thermocouple signals.

All XT series controllers are equipped with a digital input, optional buzzer and can be quickly and easily programmed using the HOT KEY programming key. The basic version also includes a TTL output for connecting the controller to serial communication.

TECHNICAL PARAMETERS
Power supply 230 Vac ±10 %, 50/60 Hz
Power consumption approx. 3VA
Accuracy at 25 °C better than ± 0.5 °C
Sampling time 1s
Front Panel Coverage IP20
Input PTC (NTC) thermistor(-50 to 140°C)
Pt 100 resistive (-100 to 500°C)
J - thermocouple (0 to 600°C)
K - thermocouple (0 to 1200°C)
S - thermocouple (0 to 1400°C)
Other inputs digital input - Voltage-free contact
Output 2x switching relay 8(3) A / 250 V
1x switching relay (alarm) 8(3) A / 250 V
Other outputs TTL output for serial communication (output for HOT KEY programming key)
DescriptionTechnical parametersDownload