Euroster 11K thermostat for fireplace insert control

Regulation of solid fuel boilers and fireplace inserts. Control of air dampers for combustion air supply and circulation pumps for heating and DHW
Euroster 11K thermostat for fireplace insert control
-18 %
List price incl. VAT 105 EUR 86,02 EUR 71,09 EUR excl. VAT
In stock
In person in Prague:tomorrowWith a delivery company:2 to 3 days
Code6-050-EU-076ProducerEurosterWarranty2 years
  • Input for 2 temperature probes and room thermostat
  • 5 relay outputs (3 pumps, 1 HVAC damper, 1 auxiliary output)
  • Panel mounting
  • Temperature sensors included
  • Promotional price
Thermostat use (heating type)For pumps
Power supply230 Vac
Switching signal transmissionWired
Output relay functionControl only / appliance up to 250W
DesignationWall-mounted
ProducerEuroster

Euroster 11K is a universal thermostat for installation in systems with a fireplace heat exchanger. It has outputs for:
- Electrically operated air damper
- heat exchanger water pump circuit
- water pump for central heating circuit or buffer tank charging
- dHW tank charging water pump
- a voltage-free relay for connecting another heat source (e.g. gas boiler)

The controller can operate in one of three systems, installation:
- Central heating via heat exchanger
- Central heating via heat exchanger
- Charging of DHW storage tank and central heating via heat exchanger

In all systems, the thermostat regulates the combustion process by controlling the throttles, depending on the measured temperature and information from the room thermostat.
Another heat source (e.g. gas boiler) is switched on depending on the measured temperature and information from the room thermostat.

The EUROSTER 11K is equipped with an ANTYSTOP system that protects the pump rotor from clogging during inactivity. Outside of the heating season, the built-in processor of the unit starts the pump or valve for 30 seconds every 14 days.

Other advantages of the EUROSTER 11K:
- Selectable hysteresis
- Clear display
- Temperature probe correction option
- Manual pump/blower switching option

TECHNICAL PARAMETERS
Power supply 230V 50Hz
Power input max. 7 mA (1.6 W)
Max pump output current 3 A
Cable lengths:
Power cord with plug
Heating pump power supply
Power supply for storage tank pump
Hot water tank probe
Boiler outlet probe

1,5 m
1,5 m
1,5 m
5 m
1,5 m
Dimensions (W x H x D) 150 x 90 x 54 mm
Hysteresis selectable 2-10°C