Euroster 11WBZ thermostat for solid fuel boilers with DHW heating

Blower speed control for boiler, heating circulator and DHW circulator power control in heating systems with solid fuel boiler or fireplace insert with heat exchanger
Euroster 11WBZ thermostat for solid fuel boilers with DHW heating
101 EUR 83,86 EUR excl. VAT
In stock
In person in Prague:nowWith a delivery company:tomorrow
Code6-050-EU-078PNreguluje dmychadlo kotle na tuhá paliva a 2 oběhová čerpaldaProducerEurosterWarranty2 years
  • Control of the blower, heating system circulator and DHW circulation pump
  • Controls the blowing force (boiler output) by changing the speed of the boiler blower (pressure fan located in the combustion air intake)
  • Terminal block for connecting sensors and outputs (sensors included)
  • Adjustable switching hysteresis
  • Temperature calibration function
  • Clear backlit display
  • Promotional price
Thermostat use (heating type)For pumps
Power supply230 Vac
Switching signal transmissionWired
Backlit displayYes
Output relay functionControl only / appliance up to 250W
DesignationWall-mounted
ProducerEuroster

EUROSTER 11WBZ is a modern microprocessor controller for controlling systems with solid fuel boiler. The device monitors the boiler water temperature and adjusts the blowing force to achieve the optimum temperature. It also starts the heating circulator and the hot water tank circulator when the desired water temperature is reached.

A single-phase asynchronous blower (push fan located in the combustion air intake) can be connected to the EUROSTER 11WBZ controller to control the boiler output, which operates on 230V 50Hz mains voltage. The speed control is solved by changing the effective value of the supply voltage of the blower (fan).

EUROSTER 11WBZ is equipped with ANTYSTOP system, which protects the pump rotor from clogging during inactivity. During the non-heating season, the unit's built-in processor starts the pump or valve for 30 seconds every 14 days.


EUROSTER 11WBZ advantages:

  • Selectable hysteresis
  • Clear LCD display - backlit
  • Temperature probes can be corrected
  • Manual pump/blower switching option
TECHNICAL PARAMETERS
Power supply 230V 50Hz
Power input max. 7 mA (1.6 W)
Max pump output current 2 A
Max blower output current 0.5A (< 100W)
Cable lengths:
Power cord with fork
Heating pump power supply
Power supply for storage tank pump
Blower power supply
Hot water tank probe
Boiler outlet probe

1,5 m
1,5 m
1,5 m
1,5 m
5 m
1,5 m
Dimensions (W x H x D) 150 x 90 x 54 mm
Hysteresis selectable 2-10°C