| Thermostat use (heating type) | Floor |
| Programming cycle | No programming |
| Power supply | 230 Vac |
| Switching signal transmission | Wireless |
| Designation | Built-in |
| Producer | Euroster |
Euroster T6RX controls thermoelectric valves for underfloor central heating (water). In addition to controlling the valve, it can also switch on/off the central heating boiler and, if all heating circuits are switched off, switch off the circulation pump. The controller works with Euroster wireless thermostats, and is suitable for controlling valves powered by 230 Vac. (both closed and open at rest heads can be used). If multiple underfloor heating loops are present in one room, it is recommended to control them simultaneously with one thermostat. The controller can switch up to 6 thermoelectric valves, one circulator (230 Vac) and has one output for boiler control. Multiple T6RX units can be connected in series to control larger systems. The T6RX controller does not control the heating water temperature, it only ensures its distribution to the heating loops. For control purposes based on heating water temperature, we recommend the Euroster 11E, 11C or 11M controllers. The actuators (valves) are not included. We recommend using Euroster T1 NC actuators.
| TECHNICAL PARAMETERS | |
|---|---|
| Power supply | 230 Vac 50Hz |
| Consumption | 1,2W |
| Maximum total output load | 3A 230V 50Hz |
| Connection of actuators (6x) | 230V 50Hz |
| Supported actuator type | thermo-electric, NO or NC |
| Installation | DIN rail mounted |
| Operating conditions | 5...40°C |
| Coverage | IP40 |
This online store saves cookies that help its proper functioning. By using our services, you agree to their use.