| Producer | Elektrobock |
Digital thermostat PT30 with the possibility of remote communication via GSM network, for use in apartments and offices. The advantage of this set-up is the simple operation, the possibility of connecting an external antenna in case of insufficient signal and the indication of the ongoing functions by means of coloured LEDs.
The kit includes a PT30 room thermostat, GSM module, antenna, power supply and data cable.
Two-way communication takes place via SMS messages between the user and the thermostat.
THE USER SENDS SMS MESSAGES FOR THE FOLLOWING FUNCTIONS:
Info - information about the status of the heating system
Off - switching off the heating system
Temperature xx - change the desired temperature (xx is the temperature value in °C, (only integers can be entered and must be within the allowed maximum and minimum temperatures, this SMS will cancel the Off function)
Call - call back
THE PT-30GST SYSTEM SENDS THE FOLLOWING SMS MESSAGES:
Specified: xx.x - is the temperature entered by the user
Act: xx.x - is the current room temperature
On - the boiler is heating
Off - the boiler is not heating
AUTO - the thermostat is in AUTO mode (switch position)
MANU - thermostat is in MAN mode (switch position)
SIG - signal strength at the installation site (0-no signal to 5-best signal)
Battery - indicates the battery in the thermostat is running low
No accept - SMS error, communication error
The PT30 GST system always sends SMS messages to a number that is stored directly in the thermostat. This number must be in international format (420 123 456 789, the 00420 format must not be used...). When using a Go card, a paid call must be made once every 3 months. This call will be made automatically (in 80 days between 4pm and 9pm) again to the first number listed in the phone book (after 20s the call will be automatically terminated).
| TECHNICAL PARAMETERS | |
|---|---|
| Thermostat PT30 | |
| Power supply | 2 x 1.5 V alkal. R6/AA |
| Number of adjustable temperatures | 6 per day |
| Hysteresis | 0.1°C to 2°C |
| Switching element | relay |
| Min. programming time | 10 min. |
| Set range. temperatures | +2°C to +39°C |
| Temperature setting | 0.5°C increments |
| Min. indication jump | 0,1°C |
| Measurement accuracy | 0,5°C |
| Output | max. 5 A |
| Operating temperature | 0°C to +40°C |
| Functions |
|