Measuring transformer 50A with RS485 and 0 to 10V output

It converts the signal from the measuring transformer to a normalized voltage signal of 0..10V and RS485 ModBus. It works with TrueRMS value of AC current.
Measuring transformer 50A with RS485 and 0 to 10V output
Measuring transformer 50A with RS485 and 0 to 10V output
Measuring transformer 50A with RS485 and 0 to 10V output (1)
Measuring transformer 50A with RS485 and 0 to 10V output (2)
142 EUR 117 EUR excl. VAT
In stock
In person in Prague:nowWith a delivery company:tomorrow
Code1P-700-130PNvstup 25 / 50A, výstup RS485 a 0..10V, napájení 12...35VdcProducerPixsysWarranty2 years

Tecnologic TA25 Measuring current transformer 25A

Tecnologic TA25 Measuring current transformer 25A
On request
28,78 EUR excl. VAT34,82 EUR
  • High precision
  • Input/output galvanically isolated
  • For measurement of direct (DC) and alternating (AC) currents
  • TrueRMS measurement of AC current value
  • 25A or 50A range selectable
  • Bipolar output selectable
  • Cannot measure direction of AC current flow
  • 0...10V output
  • RS485 ModBus output
Power supply12-24 Vac/dc
Control inputAnalog signal
Output - relay0x
Analog outputYes
Communication BusRS485
ProducerPixsys

Measuring transformer of direct and alternating currents, converting the signal value to a normalized analog voltage signal of 0...10 V. The characteristics of these transmitters ensure high accuracy of temperature reading due to the 12-bit precision A/D converter. The device is similar in function and appearance to standard active measuring transformers, but is capable of measuring TRMS DC and AC current components. The direction of current flow can only be measured for DC currents.

This version allows user configurable span and zero ranges as well as the ModBus communication address. Basic setup can be done with a DIP switch, detailed setup can be done with a library in the Pixsys HMI development tools.

TECHNICAL PARAMETERS
Dimensions 46.1 x 63 x 26.3 mm
Power supply 12...30 Vdc
Output 0...10 V
RS485 ModBus slave
Measuring range 50Arms (±50A) or 25Arms (±25A) adjustable
Maximum conversion error 0.1% of range or 0.2°C (higher of the two values)
Measurement True RMS
Resolution 12bits
0.5% of range
Isolation 3kV
Response time (10...90%) approx. 1000 ms
Overload 2kA impulse, 300A DC
Standards CE, EN 61000-6-4, EN 61000-6-2, EN 61010-1
Operating conditions -40...+85°C
30...90% RH non-condensing
Hysteresis 0.15% of range
DescriptionTechnical parametersDownload

This online store saves cookies that help its proper functioning. By using our services, you agree to their use.

Detailed settingsAllow everything