Dixell XT100C Series Comparison:
XT110C | XT111C | XT120C | XT121C | XT130C | XT131C | XT141C | |
Power supply | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac | 12, 24 Vacdc, 230 Vac |
Inputs: | |||||||
NTC, PTC, Pt100, TcJ, TcK, TcS, or 4..20mA, 0..1V, 0..10V | 1x configurable | 1x configurable | 1x configurable | 1x configurable | 1x configurable | 1x configurable | 1x configurable |
Digital input | 1x configurable | 1x configurable | 1x configurable | 1x configurable | 1x configurable | 1x configurable | 1x configurable |
Output relay: | |||||||
Stage 1 | 8A | 8A | 8A | 8A | 8A | 8A | 8A |
Grade 2 | 8A | 8A | 8A | 8A | 8A | ||
Grade 3 | |||||||
Grade 4 | |||||||
Alarm | 8A | 8A | 8A | 8A | |||
Other features: | |||||||
Communication | TTL | TTL | TTL | TTL | TTL | TTL | TTL |
Analog output | |||||||
Alarm buzzer | Optional | Optional | Optional | Optional | Optional | Optional | Optional |
Power supply | 12 Vac/dc |
Design (panel size) | 32 x 74 mm |
Type of regulation | PID |
Control input | Temperature sensor |
Auxiliary digital input | Yes |
Output - relay | 3x |
Display digit colour | Red |
Producer | Dixell |
The Dixell XT141C (in panel) models are PID controllers for temperature, humidity and pressure control with direct or inverse operation (user adjustable - e.g. heating or cooling). They are equipped with two control outputs for cooling and heating and an alarm relay. Output 1 can be set for PID, PD or ON/OFF control. Output 2 is always ON/OFF control only. Therefore, this controller cannot be used for actuator control applications. Dixell XT141C controllers can also be set up for two-stage ON/OFF control.
The analog control input can be set to PTC, NTC, Pt100, J, K, S thermocouple type probes.
All XT series controllers are equipped with a digital input, optional buzzer and can be quickly and easily programmed using the HOT KEY programming key.
The basic version also includes a TTL output for connecting the controller to serial communication using a TTL-RS485 converter.
TECHNICAL PARAMETERS | |
---|---|
Power supply | 12 Vacdc ±10 %, 50/60 Hz |
Power consumption | approx. 3VA |
Accuracy at 25 °C | better than ± 0.5 °C |
Sampling time | 1s |
Front Panel Coverage | IP65 with RG-C seal |
Input | PTC (NTC) thermistor(-50 to 140°C) Pt 100 resistive (-100 to 500°C) J - thermocouple (0 to 600°C) K - thermocouple (0 to 1200°C) S - thermocouple (0 to 1400°C) |
Other inputs | digital input - Voltage-free contact |
Output | 2x switching relay 8(3) A / 250 V 1x switching alarm relay 8(3) A / 250 V |
Other outputs | TTL output for serial communication (output for HOT KEY programming key) |