PID controller Tecnologic TLK43 LVR with analog output and one relay

universal input for CT / Pt100 / Pt1000 / PTC / NTC / analog signals; analog output 0-10V + one output relay, 24 Vac/dc power supply
PID controller Tecnologic TLK43 LVR with analog output and one relay
307 EUR 254 EUR excl. VAT
On request
In person in Prague:on requestWith a delivery company:on request
Code4T-080-370PNvstup Tč,Pt100,PTC,NTC,mA,mV,V, výstup 0..10V + 1x relé, napájení 24 Vac/dcProducerAscon TecnologicWarranty2 years

Dixell XH20P-I humidity probe

Dixell XH20P-I humidity probe
In stock
131 EUR excl. VAT159 EUR

PTC temperature probe Dixell S6.S - 2 m

PTC temperature probe Dixell S6.S - 2 m
In stock
9,25 EUR excl. VAT11,19 EUR

Pt100 temperature probe Pixsys BS 4x40 3m

Pt100 temperature probe Pixsys BS 4x40 3m
In stock
20,91 EUR excl. VAT25,30 EUR

Temperature probe - thermocouple Tecnologic FeCo - type J

Temperature probe - thermocouple Tecnologic FeCo - type J
In stock
15,68 EUR excl. VAT18,98 EUR

Refrigerant pressure sensor Dixell PP30 Male, 0 to 30bar

Refrigerant pressure sensor Dixell PP30 Male, 0 to 30bar
In stock
58,95 EUR excl. VAT71,33 EUR
  • Wide range of control settings
  • Possibility of automatic parameter setting
  • Control of regulation overrun
  • Display of setpoint and actual value simultaneously on the display
  • Completely universal controller input

Comparison of the Ascon Tecnologic TLK series of industrial controllers:

TLK31 TLK38 TLK39 TLK41 TLK42 TLK43 TLK48 TLK49 TLK94
Dimensions (mm) 78 x 35 78 x 35 78 x 35 48 x 48 48 x 48 48 x 48 48 x 48 48 x 48 48 x 96
Power supply 12 Vacdc 12, 24, 100-240 Vacdc 12, 24, 100-240 Vacdc 24, 100-240 Vacdc 24, 100-240 Vacdc 24, 100-240 Vacdc 24, 100-240 Vacdc 24, 100-240 Vacdc 24, 100-240 Vacdc
Display 1 line 1-line 2-line 1-line 2-line 2-row 1-line 2-row 2-row
Analog input PTC, NTC, TcJ, TcK, TcS, Pt100, mV, V, mA PTC, NTC, TcJ, TcK, TcS, Pt100, mV, V, mA PTC, NTC, TcJ, TcK, TcS, Pt100, mV, V, mA Universal Universal Universal PTC, NTC, TcJ, TcK, TcS, Pt100, mV, V, mA PTC, NTC, TcJ, TcK, TcS, Pt100, mV, V, mA Universal
Digital input optional optional optional
Relay/output for SSR 4x 2x 2x 4x 4x 4x 3x 3x 5x
Analog output 2x optional 2x optional
Retransmit setpoint optional
On/Off and PID control yes yes yes yes yes yes yes yes yes
Regulation of actuators optional optional
RS485 optional optional optional optional optional
Timer function
Programmer function

Power supply24 Vac/dc
Design (panel size)48 x 48 mm
Type of regulation2xPID
Control inputUniversal
Output - relay1x
Analog outputYes
Display digit colourTwo colours
ProducerAscon Tecnologic

Ascon Tecnologic TLK43 microprocessor controllers support these types of control:

  • ON/OFF
  • ON/OFF with neutral zone
  • PID with single-acting and double-acting control
  • PID for servo drive control with time-dependent positioning

Ascon Tecnologic TLK43 are equipped with Autotuning and Selftuning functions and Fuzzy control for PID control. The PID control is performed in a two degree of freedom algorithm and optimizes the instrument function independently of process disturbances and setpoint changes.
Furthermore, the controller can communicate over the RS485 serial communication link via the MODBUSRTU public protocol with a baud rate of up to 38,400 baud.
The actual value is shown in red on the upper 4-digit display and the setpoint in green on the lower 4-digit display. The status of the outputs is indicated by 4 LEDs. The controller allows 4 setpoints to be stored in memory and can have up to four outputs: relay or solid state relay SSR.
The input of the device is universal and programmable. It can be connected to thermocouples (J,K,S, B, C, E, L, N, R, T), Pt100 and Pt1000 RTDs, PTC and NTC thermistors, Tecnologic infrared sensors and standardized analog signals (0/4 to 20 mA, 0/1 to 5 V, 0/2 to 10 V, 0 to 50/60 mV, 12 to 60 mV). Versions of the controllers with four outputs also allow the fourth output to be set as a digital input.
The controller can be equipped with a current transformer at the input to measure the current through the load - HEATER BREAK ALARM function.
Other important functions of the controller are :

  • alarm in case of a control loop failure
  • reaching the desired value at the selected speed
  • ramp and delay function
  • soft start function
  • pC configuration
  • parameter protection with different access levels

TECHNICAL PARAMETERS
Power supply 24Vac/dc, ±10%
Power consumption approx. 10 VA
Input j,K,S thermocouple (-270...1760°C)
thermocouple B,C,E,L,N,R,T ( TLK43 only)
resistance Pt100, Pt1000 (-200...850°C)
pTC, NTC thermistor (-50...150°C)
current (0/4...20mA)
voltage (0/12...50/60mV, 0/1...5V, 0/2...10V)
tecnologic IRS infrared sensor
Outputs 1x switching relay 5(2)A, 250Vac
1x analogue signal 0/2...10V
Sampling time 130 ms
Accuracy ± 0.15 % of range
Dimensions 48 x 48 mm, depth 98 mm
Mounting hole 45 x 45 mm
Coverage faceplate IP54 with seal, terminals IP20 with cover