| Power supply | 230 Vac |
| Design (panel size) | Other |
| Type of regulation | PID |
| Control input | Temperature sensor |
| Output - relay | 2x |
| Display digit colour | Two colours |
| Producer | Pixsys |
The Pixsys ATR902 allows programming of 15 cycles/programs, up to 18 steps/segments, all steps freely adjustable by the operator as rise/stay/decay. A distinctive feature is the very user-friendly programming and easy operation even for unskilled operators.
The Pixsys ATR902 is designed specifically for hobby kilns, but is also suitable for professional applications such as ceramics/glass/jewelry/dental stone or laboratory kilns that require time-dependent temperature control. Options include special functions such as delay start, wait (useful if the process has a delay from the programmed setpoint), recovery cycle (after an unexpected power failure). The multi-pole connector does not require interference with electrical wiring and allows direct installation/replacement.
Analog input is configurable for different thermocouple types (no separate ordering codes), two output relays are programmable as control/alarm/auxiliary. All options can be entered via the keypad.
| TECHNICAL PARAMETERS | |
|---|---|
| Dimensions | 120 x 65 (front panel) x 65 mm |
| Power supply | 24...230 Vacdc ±15% 50/60 Hz |
| Consumption | 4 W |
| Display | 4 digit 0.56" red + 4 digit 0.4" green + bar graph |
| Working conditions | Temperature 0-45 °C, humidity 35..95 %RH |
| Material | Box: ABS; front panel: polycarbonate |
| Weight | approx. 550 gr |
| Coverage | IP65 (front panel) , IP20 (Box and terminal block) |
| Accessories | Connector 7 pins/single (furnace side), panel mounting bracket |
| Input | TC K, S, R, J, T, E, N optional parameter |
| Output | 1x relay 8A - 250 Vac 1x Relay 8A - 250 Vac alarm/auxiliary |
| Control | ON-OFF with hysteresis, P/PI/PID control |
| Tuning | Automatic, automatic with anticipation |
| Data protection | Parameter access via password, change setpoint during cycle via parameters only |
| Alarm mode | Absolute / relative, band, upper / lower deviation, time programmable for one step |
| Hold function | Hold current setpoint with Start/Stop buttons |
| Wait function | Special function to compensate for SPV / PV differences in case of system overload |
| Cycle recovery function | Cycle recovery after unexpected power failure |
| Setpoint control mode | Regulation to a constant setpoint (function can be enabled from the general menu or during a running cycle) |