Produal HDK temperature and CO2 sensor for air handling systems

Air temperature and CO2 level sensor, for air ducts, output 3x 0...10V
Produal HDK temperature and CO2 sensor for air handling systems
523 EUR 432 EUR excl. VAT
Over a week
In person in Prague:on requestWith a delivery company:on request
CodePR-113-5050PNdo VZT, 0...+50°C, 0...2000ppm CO2, výstup 3x 0...10V, rozměry 105 x 104 x 155 mmProducerProdualWarranty2 years

Produal ML-SER configuration instrument

Produal ML-SER configuration instrument
Over a week
183 EUR excl. VAT222 EUR
  • For use in air distribution systems
  • Temperature andCO2 level measurement
  • Output 3x 0...10V (temperature +CO2 + control programmable analog output)
  • ABCLogic automatic calibration to prevent long-term drift
Measured quantityRefrigerants / Hazardous gases / CO2 / Dust
Measuring part of the sensorStandard
Cable lengthNo cable
Measured temperature rangeworse than -30..+80°C
DesignationBuilt-in
ProducerProdual

Produal HDK are sensors designed to detect and control carbon dioxide concentration, temperature and humidity inside ventilation ducts. The sensor can also be used for demand-based ventilation control. The N model allows the measured values to be displayed on a display. The setpoint can be locked to display continuously on the display. The ABCLogic™ self-calibration method eliminates possible long-term characteristic drift. The ABCLogic™ function can be disabled using the ML-SER tool.
The control output can be controlled either by a single measured value or by the maximum of all values. The sensor settings can be changed using the ML-SER tool.
The transmitter can be equipped with an HD-R relay (24 Vac, 1 A). The relay output can also be controlled by one measured value or by all measured values. The relay output can be set using the ML-SER tool.

The selling price shown is retail price, for single unit sales. If you require multiple units, please feel free to contact us for a significantly better price.

TECHNICAL PARAMETERS
Measuring range - temperature
Measuring range -CO2
0 ... +50 °C
0 ... 2000 ppm
Accuracy - temperature
Accuracy -CO2
± 0,5 °C
± 40ppm +3% of value
CO2 time constant < 2 min
Long-termCO2 stability < 2% of range
Stem dimension O 10 x 110 mm
Outputs 3x 0...10 V (<2 mA)
Coverage IP54
Dimensions 105 x 104 x 155 mm