Tecnologic TLB30S YYYBV split thermostat with large red display

Separate control solution for cooling equipment. Logic with display (31mm digit height) can be placed in a different location than the power part of the controller
Tecnologic TLB30S YYYBV split thermostat with large red display
Tecnologic TLB30S YYYBV split thermostat with large red display
Tecnologic TLB30S YYYBV split thermostat with large red display
86,34 EUR 71,36 EUR excl. VAT
In stock
In person in Prague:tomorrowWith a delivery company:2 to 3 days
Code4T-022-000PNčervený displej 50x96 mm + silový modul, 2 x PTC, NTC, napájení 110-230 Vstř., 3 x reléProducerAscon TecnologicWarranty2 years

Thermostat for cooling - power module BSLB4 HRRRRV

Thermostat for cooling - power module BSLB4 HRRRRV
On request
5,12 EUR excl. VAT6,20 EUR

PTC temperature probe Dixell S6.S - 2 m

PTC temperature probe Dixell S6.S - 2 m
In stock
9,27 EUR excl. VAT11,22 EUR

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,64 EUR excl. VAT5,61 EUR
  • Control unit with display + separate power outputs (TLBSL) that connect via cable (TLBCA)
  • Red touch screen, 50 x 96 mm, digit height 31mm
  • Soft touch control technology
Power supply230 Vac
Design (panel size)Other
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay3x
Display digit colourRed
ProducerAscon Tecnologic

Models TLB 30 and TLB 55 (display and control unit) and TLBSL (power supply and output module) are digital devices controlled by a microprocessor. They are suitable for cooling with ON/OFF temperature control and defrosting with heating rods or hot steam (reversing).
The TLB30 and TLB50 control units are functionally identical, differing only in mechanical dimensions.
The unit has 3 relay outputs, 2 inputs for PTC or NTC temperature sensors and 2 configurable digital inputs. The outputs (TLBSL module) are used for compressor control or temperature control devices, for defrost and evaporator fan control. They can also be used as an alarm or auxiliary output.
The two inputs of PTC or NTC temperature sensors (which can be parameterized) connected to the TLB30 or TLB55 unit are used to measure room temperature (Pr1) and evaporator temperature (Pr2). The digital inputs (DIG1, 2) can be programmed for various functions - defrost start, selection of two or four control setpoints, external alarm signaling, continuous cycle activation and auxiliary relay activation. In addition, the unit is equipped with alarm and shutdown control outputs in case of too high or low supply voltage. The instrument has a large two-digit display (TLB30 - height 31mm, TLB55 - height 54mm ) with three LED status indicators. Parameter programming is possible via the touch screen or via a remote keypad(TLBTA-not included) connected to the TLB30 (TLB55) unit. The connection of the TLBSL module to the unit is via a cable (TLBCA) with RJ connectors.

TECHNICAL PARAMETERS
Power supply 100..240 VAC ±10% 50/60 Hz
Consumption approx. 4 VA
Inputs 2x PTC / NTC
2x digital voltage-free input
Outputs 1x SPST-NO 16A / 250 VAC
1x SPDT 8A / 250 VAC
1x SPST-NO 5A / 250 VAC
Temperature control On / Off
Defrost control interval in cycles, electrically or by hot steam / cycle reversal
Measuring range PTC: -50...99 °C
NTC: -50...99 °C
Display resolution 1° or 0.1°
Overall accuracy ±0.5% of ±1 digit range
Sampling time 130 ms
Dimensions TLB30: 96 x 50mm, depth 22.5mm
TBSL: 90 x 65 mm, depth 41 mm
TLB30/55 front panel rating IP 65 (NEMA 3S) with gasket
Operating conditions 0 - 50 °C, < 95% non-condensing
DescriptionTechnical parametersDownload