Carel cooling thermostat DN33S0EA00 for DIN rail

230 Vac power supply, 2x NTC input, 3x digital input, 2x output relays for compressor and defrost
Carel cooling thermostat DN33S0EA00 for DIN rail
139 EUR 115 EUR excl. VAT
On request
In person in Prague:on requestWith a delivery company:on request
Code5C-170-015PN2x NTC vstup, 3x digitální vstup, 2x výst.relé, bzučák, RS485 konektor, verze na DIN lištuProducerCarelWarranty2 years

Dixell NG6 NTC temperature sensor

Dixell NG6 NTC temperature sensor
In stock
4,73 EUR excl. VAT5,72 EUR

Dixell NS6 NTC temperature probe

Dixell NS6 NTC temperature probe
In stock
6,41 EUR excl. VAT7,76 EUR

Warning: this and other termostats DN33 were replaced by an universal thermostat Carel U20R00UC00250.

  • Two output relays, 16A for compressor, 8A for defrost
  • 2x NTC input
  • 3x digital input
  • Buzzer for local alarm reporting
Power supply230 Vac
Design (panel size)DIN
Type of regulationOn/off
Control inputTemperature sensor
Auxiliary digital inputYes
Output - relay2x
Communication BusRS485
Display digit colourGreen
ProducerCarel

Carel DN33S0EA00 (Carel ir33DIN) models are suitable for controlling cooling units (without evaporator fan) with above-zero and below-zero temperatures. The controllers display the temperature and switch the compressor (or solenoid valve) according to the desired value. They can also automatically defrost by reversing the compressor or heating rods according to set time parameters. The controller can be used for temperature control during cooling (direct mode) or heating (inverse mode). These functions can be easily selected by changing a parameter or digital input.

The Carel DN33S0EA00 thermostat can operate not only individually, but also in a local network using external control (synchronization), without the need to lay additional cables. This feature is particularly useful and efficient in multi-cabinet applications where the entire operation of the installation must be controlled in synchronisation, especially with regard to defrosting. Defrosting starts simultaneously in all sections and ends independently, depending on the status of each section. When defrosting is complete, the next cooling phase starts synchronously on all sections. The local network can be used to centralize and synchronize not only the defrosting, but all functions on one display. This means that when the lighting button is pressed, for example, the command is transmitted for serial connection to all controllers, which activate the lighting relay at the same time. The same applies to the on/off, manual defrost, continuous cycle and auxiliary function commands.

TECHNICAL PARAMETERS
Power supply 230 Vac, ±10%, 50-60Hz
Power consumption depending on model 3 - 6 VA
Inputs 2 x NTC
3 x digital voltage-free
Outputs 1x 16A 250Vac relay for compressor
1x 8A 250Vac relay for defrost
Dimensions 70 x 110 x 60 mm
(4 DIN modules)
Front panel enclosure IP40
Operating conditions 0...60°C, 20...80% humidity
DescriptionTechnical parametersDownload

This online store saves cookies that help its proper functioning. By using our services, you agree to their use.

Detailed settingsAllow everything